Two peg test results tell you whether an auto level's line of sight is truly horizontal. You set two pegs about 60 metres apart, read a staff from the midpoint, then from about 3 metres from one peg, and compare the two height differences. If they differ by more than a few millimetres, the level needs adjustment.
We sell automatic levels from Rawalpindi and check them on our bench every week. The two peg test is the one check every site engineer should be able to do without us. It takes 20 minutes, needs only the level, a tripod, a staff and two firm pegs, and it catches the most common fault in levelling: a line of sight that is tilted a few seconds up or down.
What is the two peg test and why does it work?
An auto level is meant to give a horizontal line of sight wherever you point it. In practice, after knocks, heat and road journeys, the line of sight tilts slightly. That tilt is called collimation error. It produces an error in every staff reading that grows with distance: zero at the instrument, a few millimetres at 30 metres, more at 60.
The trick of the two peg test is that when the instrument is exactly midway between two staffs, both readings carry the same error, so it cancels in the difference. That gives you the true height difference between the pegs. When you then set up close to one peg, the near reading has almost no error and the far reading carries almost all of it. Compare the two differences and you have measured the error.
How do you do a two peg test?
- Choose flat, firm ground with a clear 60 metre line. A road in a housing society early in the morning is ideal.
- Set peg A and peg B 60 metres apart. Use nails in concrete or steel pins, not timber pegs in soft soil.
- Set up the level exactly midway, 30 metres from each peg. Pace or tape it: equal sight lengths are the whole point.
- Read the staff on A, then on B. Call these a1 and b1. Take each reading twice.
- Work out the true difference: a1 minus b1.
- Move the level to about 3 metres from peg A, on the line between the pegs.
- Read A, then B again. Call these a2 and b2.
- Work out the apparent difference: a2 minus b2.
- Compare. If the apparent difference equals the true difference to within your tolerance, the level is in adjustment.
Two Pakistani details matter. Do the test before about 10 am between April and October, because heat shimmer over a road in Lahore or Hyderabad makes a 57 metre reading jump by several millimetres. And hold the staff vertical with a staff bubble; a staff leaning back by a few degrees reads high and gets blamed on the instrument.
Worked example: a two peg test with real numbers
These are typical readings in metres, of the kind we see from a level that has taken a knock in a pickup.
| Set up | Distance to A (m) | Distance to B (m) | Staff on A (m) | Staff on B (m) | Difference A minus B (m) |
|---|---|---|---|---|---|
| Midway | 30 | 30 | 1.425 | 1.168 | 0.257 (true) |
| Near A | 3 | 57 | 1.512 | 1.261 | 0.251 (apparent) |
| Gap between the two | 54 m longer to B | 0.006 (6 mm) |
The apparent difference is 6 mm smaller than the true one. The far reading on B should have been 1.512 minus 0.257, which is 1.255, but the level read 1.261. The line of sight is tilted upwards.
What is the formula for collimation error?
Collimation error per metre equals the gap between the two differences divided by the difference in sight lengths.
In the example: 0.006 m divided by (57 minus 3) m gives 0.000111, or about 0.11 mm per metre. In angle that is roughly 23 seconds of arc. Over the 60 metre test line the error is just under 7 mm.
To find the corrected reading at B from the near set up, subtract the error over 57 metres: 1.261 minus (57 x 0.000111), which is about 1.255. That is the reading you set the crosshair to if you adjust the reticle.
What tolerance is acceptable?
There is no single number that every job uses. ISO 17123-2 sets out field procedures for testing levels, and many consultants and site manuals set their own limit. In common practice on Pakistani building and road sites, a level is accepted when the gap is within a few millimetres over the 60 metre set up, with tighter limits for precise work such as long sewer and canal gradients.
| Gap over the 60 m test | What it means | What to do |
|---|---|---|
| 0 to 2 mm | In adjustment for almost all site work | Record the test, carry on |
| 2 to 4 mm | Acceptable for most construction levelling | Keep back and fore sights equal, retest soon |
| 4 to 6 mm | Out of adjustment for gradients and long lines | Adjust the reticle or send it in |
| Over 6 mm | Unreliable | Stop levelling, send it to the bench |
In the worked example the 6 mm gap is in the last band. That level should not carry a WAPDA canal bed or a CDA sewer gradient until it is adjusted.
Keeping back and fore sights equal on every set up cancels most collimation error, which is why an old level still gives good closures for a careful crew. It is no excuse to leave the error in: crews in a hurry on a Rawalpindi site rarely pace their sights.
When to adjust it yourself and when to send it to the bench
Many auto levels have a reticle adjusting screw under a cover behind the eyepiece. With the instrument still set up near A, you turn it gently until the crosshair reads the corrected value on B, then repeat the whole test. If you have done it before, it is a 10 minute job.
Before you touch that screw, do one more check. Repeat the near set up twice: once with the circular bubble centred, once with it deliberately off-centre towards the edge of its ring. If the reading on B changes by more than a millimetre, the compensator is sticking or damaged, and no reticle adjustment will fix it. A compensator fault is the most common reason we see a level that "fails the peg test again a week after adjusting".
Send it to the bench when:
- the compensator check above fails
- the gap is over 6 mm, which usually means a knock or a fall
- the crosshair is not sharp or the image is hazy, a sign of moisture or fungus after a monsoon
- you need a calibration certificate for a consultant or a tender
Our total station repair and calibration bench in Rawalpindi checks and adjusts automatic levels as well as total stations, tests the compensator, and issues a certificate.
What we supply
Our levels are under auto levels, and staffs and tripods under tools and accessories.
- NA32 automatic level: the dependable site level.
- Orion+ automatic level: value level for building work.
- Sokkia B series automatic level: Japanese compensator for long, precise lines.
- Levelling staff and ranging rod and an aluminium survey tripod.
- Instrument calibration and repair when the test fails.
If the level is new to your crew, start with how to use an auto level. For prices, read auto level price in Pakistan, and for tripods that hold height in heat, survey tripod and prism price in Pakistan.
Ask for today's price
If your level failed the test, send us the readings and the model on WhatsApp and we will tell you whether it is an adjustment or a bench job. If you need a new level, we will confirm today's price. Send us a WhatsApp.
What we supply
Equipment covered in this guide
Orion+Orion+ Automatic Level
A compensator level that settles fast and stays settled. The one we hand a site engineer who levels every day and has no time to fuss with it.
NA32NA32 Automatic Level
The classic 32x automatic level. Simple, repairable and still the most common instrument on a Pakistani site.
SokkiaB20 / B30 / B40Sokkia B Series Automatic Level
Automatic levels for setting out and levelling runs, with a magnetically damped compensator that settles fast in site wind.
FAQ
Questions buyers ask us
What is the two peg test?
The two peg test is a field check of an auto level's line of sight. You read a staff on two pegs about 60 metres apart, first from the midpoint and then from close to one peg. If the two height differences disagree by more than a few millimetres, the line of sight is tilted.
What is the formula for collimation error in a two peg test?
Take the true difference from the midpoint set up, (a1 minus b1), and the apparent difference from the near set up, (a2 minus b2). The error is the gap between them divided by the difference in sight lengths. A 6 mm gap over 54 metres is about 0.11 mm per metre.
What is a peg in surveying?
A peg is a fixed point you can return to, usually a timber stake with a nail, a steel pin or a nail in concrete. For a two peg test it must not move by even 1 mm between readings, so on soft monsoon ground use steel pins driven at least 300 mm deep.
How often should I do a two peg test?
Do it at the start of every major levelling job, once a month on a busy site, and after any knock, fall or long road journey. It takes about 20 minutes. Many consultants on NHA and housing society work ask to see a peg test record dated within the last 30 days.
What are the two types of levelling booking?
The two common booking methods are rise and fall, and height of collimation. Rise and fall gives a full arithmetic check on every intermediate sight, while height of collimation is quicker with many intermediate sights. Both should close within a few millimetres on a 1 kilometre loop.
Can I adjust an auto level myself after a failed peg test?
Many auto levels have a reticle adjusting screw behind the eyepiece cover, and an experienced surveyor can move the crosshair to the corrected reading in 10 minutes. If the error changes when the bubble is offset, the compensator is at fault, and that needs a bench.